Wastewater treatment is an essential part of hospital operation. Medical wastewater may contain pathogenic microorganisms, pharmaceutical residues, disinfectants, organic matter and other contaminants; if it is not properly collected and treated, it can create environmental and public-health risks. Chlorine dioxide has become one of the disinfection technologies used in hospital wastewater treatment because of its strong oxidizing capability and its different reaction characteristics from free chlorine. However, its advantages should be evaluated together with wastewater quality, process conditions, by-product control, safety management and applicable discharge requirements.

Broad-Spectrum Microbial Inactivation
Chlorine dioxide is a strong oxidizing disinfectant that can inactivate many bacteria, some viruses, fungi and, under sufficiently stringent conditions, certain resistant microbial forms. Its action is associated with oxidation of proteins, sulfur-containing amino acids, membrane-related structures and other essential cellular components. However, it is not technically correct to state that its disinfection performance is universally far superior to liquid chlorine or sodium hypochlorite; the result depends on concentration, contact time, temperature, suspended solids, organic load and the target microorganism.
For common pathogens such as Escherichia coli and Salmonella, chlorine dioxide can provide effective inactivation under validated conditions. Claims such as “two to five times more effective than chlorine disinfectants” should not be used as a universal conclusion unless the test conditions are specified. The same applies to viruses: performance must be evaluated for the specific virus and process conditions. Norovirus is a non-enveloped virus, so it should not be grouped with enveloped viruses. For hospital wastewater, microbial control should ultimately be confirmed against the applicable discharge standard and monitoring results rather than by a generalized superiority ratio.
Chlorine dioxide can also contribute to biofilm control because of its oxidizing and diffusion properties, but mature biofilms are complex structures containing extracellular polymers and organic matter that consume oxidant and protect deeper microorganisms. Therefore, it is more accurate to say that chlorine dioxide can be part of a biofilm-control program, usually together with cleaning, hydraulic management and validated disinfection, rather than claiming that it always penetrates and completely removes established biofilm communities.

(Xiuba chlorine dioxide products may be evaluated for hospital wastewater disinfection where the product scope and project conditions are appropriate.)
A Different By-Product Profile from Conventional Chlorination
Compared with free chlorine, chlorine dioxide reacts differently with organic matter and can reduce the formation of some typical halogenated organic disinfection by-products under suitable conditions. This can be an important process advantage, but it should not be described as producing virtually no harmful by-products.
Liquid chlorine and sodium hypochlorite can react with organic matter to form trihalomethanes, haloacetic acids and other halogenated by-products. Some of these compounds are subject to health and environmental concern, but it is too broad to describe all of them simply as carcinogens. Their formation depends on organic precursors, chlorine dose, pH, contact time and other water-quality conditions.
Chlorine dioxide acts mainly through oxidation rather than the typical chlorination pathway and, unlike free chlorine, does not react with ammonia in the same way. Nevertheless, chlorine dioxide treatment produces its own transformation products, particularly chlorite and chlorate, which may require control. In some generator routes, chlorine may also be present. Therefore, a more accurate conclusion is that chlorine dioxide changes the by-product profile and may reduce some conventional halogenated by-products, rather than that it automatically reduces overall effluent toxicity or makes the treated wastewater intrinsically safer.

Relatively Lower Sensitivity to pH Changes
One operational advantage of chlorine dioxide is that its disinfection performance is generally less sensitive to pH variation than that of free chlorine. This can simplify process control in some hospital wastewater applications, but it does not mean that performance is identical at every pH value.
The disinfection efficiency of free chlorine is strongly influenced by the balance between hypochlorous acid and hypochlorite ion, so alkaline conditions can reduce its effectiveness. Chlorine dioxide is relatively less affected by this equilibrium, but statements such as “stable performance from pH 4 to 10 with no need for pH adjustment” are too absolute. Actual performance should still be confirmed according to wastewater composition, temperature, organic load, target microorganisms and validated CT conditions.
Odor and Color Control as an Additional Oxidation Benefit
Hospital wastewater may contain sulfides, phenolic compounds and other substances that contribute to odor or color. Chlorine dioxide can oxidize some of these compounds and may therefore improve certain odor and color characteristics. However, the extent of improvement depends on contaminant type, dose and reaction conditions, and disinfection should not be confused with complete removal of all odor- or color-causing substances.
Chlorine dioxide can also oxidize some dissolved iron and manganese species into forms that are easier to remove by downstream sedimentation or filtration. Oxidation itself is not the same as removal: the resulting particulate oxides still need a suitable solid-liquid separation step. It is therefore inaccurate to say that chlorine dioxide alone directly removes iron and manganese, or that this capability is entirely absent from all chlorine-based systems.
Residual Control Must Be Based on the Process, Not on “Longer Protection”
Under suitable water-quality conditions, chlorine dioxide can maintain a measurable residual for a period of time, which may help suppress microbial regrowth in some water systems. However, its decay rate is not universally slower than that of all chlorine disinfectants, and the idea of providing “longer protection during wastewater discharge” should not be treated as a general treatment objective. For hospital wastewater, the priority is to achieve the required microbial and pollutant limits while controlling residual oxidant and environmental risk at the discharge point. Residual behavior depends on organic load, reducing substances, temperature, retention time and process design.

Safety Advantages and New Safety Responsibilities
Liquid chlorine involves significant storage and leakage hazards, and sodium hypochlorite can be corrosive and loses available chlorine during storage. On-site generation of chlorine dioxide can reduce the need to transport or store concentrated chlorine dioxide itself, which is an advantage. However, it does not remove safety risk: generators require chemical feed management, ventilation, leak detection, interlocks, compatible materials and trained operators. Depending on the generation route, acids, chlorite or chlorate feedstocks also require appropriate segregation and storage. Safety should therefore be assessed across the entire system rather than by the disinfectant name alone.
Potential Role in Controlling Selected Micropollutants
Hospital wastewater may contain antibiotics, disinfectants and other organic micropollutants. Chlorine dioxide can oxidize some compounds, but removal efficiency varies greatly with molecular structure, dose, pH, competing substances and contact time. It should not be stated broadly that chlorine dioxide can effectively decompose these pollutants and reduce ecological toxicity in all cases. Where control of pharmaceuticals or other new pollutants is an important objective, specific treatability testing and, where necessary, additional advanced-treatment processes should be considered.

Overall, chlorine dioxide is an important option for hospital wastewater disinfection because of its broad microbial activity, relatively lower pH sensitivity and different by-product profile from free chlorine. At the same time, it introduces control requirements for chlorite, chlorate, generation-system safety and process monitoring. It should therefore not be described as universally superior to liquid chlorine or sodium hypochlorite. The correct technology should be selected according to wastewater characteristics, discharge route, applicable standards, operating capability, safety requirements and life-cycle cost. China’s GB 18466-2005 was amended in 2026, further strengthening requirements for medical wastewater risk control, so current projects should use the applicable version of the standard together with local discharge and permit requirements.